Contact Us

TEL:+86-533-2171222

FAX:+86-533-2171222

Mob:+8618753366306

E-mail: zhangzengwei@cnpowercable.cn

ADD:No. East 2. Zhangdian District Zibo City Shandong P.R. China

Home > News > Content
Low Voltage XLPE Insulated Wire Armoured Cable (YJLV) Mar 24, 2017
Basic Info
  • Model NO.: YJLV

  • Conductor Type: Stranded

  • Conductor Material: Aluminum

  • Insulation Material: XLPE

  • Range of Application: Mine

  • Brand: Dragon Brand

  • Color: Black/ as Your Request

  • OEM&Ome: Yes

  • Transport Package: Steel Drum, Wooden Drum, Steel Wooden Drum

  • Origin:Sichuan,China

  • Type: Insulated

  • Application: Underground

  • Sheath Material: PVC

  • Material Shape: Round Wire

  • Certification: ISO9001, CE, UL, CCC

  • Rated Standard: IEC

  • Rated Voltage: 1.8/3kv

  • Specification: CE/CCC/IEC

  • HS Code: 85441100

Product Description

Low Voltage XLPE Insulated  Wire Armoured Cable (YJLV)
 
Model Number

YJLV
1.8/3kV

Brand Name
Jiaguan
Place of OriginXingtaiStandardsTICW/04-2009
TypeLow voltage  cablesRated Voltage1.8/3kV
Insulation MaterialXLPEConductor MaterialAluminum
Jacket MaterialPVCInner Sheath MaterialPVC
Number of cores1-3Cross-sectional area  mm225-630
Armored       MaterialNOColorRed, green, yellow and blue or black according to customer requirements
CertificateISO9001,CCCMOQ100 meters
OEM/ODMYESSampleFree samples
Payment TermsT/T,L/C,or according to the final negotiationDelivery detailsAccording to the quantity of order.   15-20 days for delivery after got the deposit
 
Structure Size :

        
SpecificationConductor structureConductor diameter
(mm)
Insulation thickness
(mm)
Taping Specifications
(mm)
Metal shield Specifications
(mm)
Sheath thickness(mm)Reference outer diameter
(mm)
Reference Weight
(kg/km)
1×257/2.166.02.020×0.200.121.414.3223.5
1×357/2.527.02.020×0.200.121.415.3265.3
1×5010/2.528.42.020×0.200.121.416.7321.1
1×7014/2.5210.02.020×0.200.121.518.6405.9
1×9519/2.5211.62.025×0.200.121.520.2495.2
1×12024/2.5213.02.025×0.200.121.621.8592.3
1×15030/2.5214.62.025×0.200.121.623.4695.5
1×18537/2.5216.22.025×0.200.121.725.2824.1
1×24048/2.5218.52.025×0.200.121.827.71018.1
1×30061/2.5220.62.030×0.200.121.829.81209.3
1×40061/2.9423.32.030×0.200.121.932.71614.8
1×50060/3.2926.62.230×0.200.122.036.61891.1
1×63060/3.6929.62.435×0.200.122.240.52353.4
3×257/2.166.02.025×0.200.101.827.5884.2
3×357/2.527.02.030×0.200.101.829.71059.3
3×5010/2.528.42.030×0.200.101.932.91313.8
3×7014/2.5210.02.030×0.200.102.036.61657.3
3×9519/2.5211.62.035×0.200.102.140.22044.8
3×12024/2.5213.02.035×0.200.102.243.42424.5
3×15030/2.5214.62.035×0.200.102.347.12888.1
3×18537/2.5216.22.040×0.200.102.551.03418.2
3×24048/2.5218.52.040×0.200.102.656.24209.9
3×30061/2.5220.62.040×0.200.102.861.15056.6
 

16.jpg20.jpg23.jpg

 
  
Applications:

1. This product is suitable for power lines that AC 50Hz, rated voltage 1.8 / 3kV (the maximum system voltage 3.6kV) for power transmission.

2. To be fixed in metallurgy, electricity, building etc., and To be fixed in cable channel, pipeline, direct burial .
  
Product Features:

1.Widely source of raw materials with low cost, and easy for processing and manufacturing.

2.The product uses cross-linked polyethylene insulation, compared with PVC insulated cables, has good insulation properties, high temperature conductors, can up to 90 degrees.

3.This product uses steel armor, can withstand greater mechanical stress.

Operating Property:

 
ItemsDescription
Rated Voltage
 
Frequency AC rated voltage is 0.6/ 1kV. The maximum voltage of using AC system is no more than 1.2kv
Operating TemperatureThe long-term maxmium operating temperature of cable conductor is 90 ºC. When in short circuit, the maximum temperature is no more than 250 ºC,time of duration is no more than 5 S.
Environment TemperatureMinimum operating temperature temperature is -10 ºC.
Laying temperatureOnce installed, the laying temperature should not be less than 0 ºC.
Bending radiusThe bending radius of single-core cable is not more than15 D, the bending radius of multi-cores cable is not more than 12 D.
StorageFinished cable should be stored at 0 ~ 40 ºC, humidity is below 85% of the environment, and avoid direct sunlight and the rain, keep ventilation and dry environment. According to the above requirements for storage and use, the cable can be used for more than 25 years long.
Installation InstructionWhen installed, the environment temperature should not be lower than 0 ºC,if the environment temperature is lower 0 ºC, the cable should be preheated before installation, the bending radius should be controlled strictly, Single cable bending radius should be not less than 20D, multi-core cable bending radius should be not less than 15D. so as to avoid mechanical damage about internal cables (D is the cable diameter).

Guarantees :

1) Factory Direct and on-time shipment.
2) Finest available raw materials, Strict quality control system
3) Customized sizes, OEM are accepted!
4) Goods are sold with rerun or refund guarantee due to quality issue!
Shipping terms
1) We accept terms of delivery EXW, FOB, CFR, CIF, etc.
2) Sample time: 3-5 days..
3) Production time: 7-30 days (Depends on the Qty) upon advanced payment received.
4) Packing: export standard cartons, drums or customized as customers' requests.
 
 
If you have any questions , please feel free to contact me .

Contact Person : Jennifer Zhang

Mobile: 0086-13792166807    Website: www.cnpowercable.cn

E-mail: jennifer@cnpowercable.cn . wechat:109277052. whatsApp:+86 13792166807.skype: +86 13792166807??